Technology for the Welders World.  
     
ROBO Anti-Spatter TMS-PI Internal Injector
The ABICOR Binzel® TMS-PI Anti-Spatter Injector is essential to front end welding torch maintenance, providing an adjustable, measured amount of anti-spatter fluid with the torch airblast. All ABICOR Binzel robotic torches are equipped with airblast capability. For maximum spatter removal, the Airblast Anti-Spatter can be used in conjunction with the ABICOR Binzel TCS-6 Cleaning Station.
Working Pressure: 6-8 bar/85-120 psi
Inlet Connection: 1/4" hose barb
Reservoir Capacity: 32 oz
Requirements: 1 output
24 VDC or 110 VAC
24 VDC: 0.3 Amps, Max @ 6 watts, 250 mA operating
•Robotics Brochure (pdf format)
•Industrial Trade Price List (Excel format)
 
Model
Part No.
TMS-PI Internal Injector Anti-Spatter Unit 24VDC, 16 oz
832.9100-HF

ITEM NO.
DESCRIPTION
SPECIFICATIONS
PART NO.
-
TMS-PI Hi-Flow Anti-Spatter Internal Injector 24VDC/110VAC
-
832.9100-HF
1
Reservoir
32 oz
832.9104
2
Mounting Block Top
-
832.9134
3
Injector Body Bottom
-
832.9135
4
Solenoid Valve 24VDC/110VAC with 15' cord
-
832.9135
5
Pulse Generator
-
832.9112
6
Bracket Mounting
-
832.9113
7
Screw Bracket, M6 x 75 (included with Item 6)
2 Required
832.9138
8
Hose Outer 1/4 ID
per meter
176.0008
9
Hose Inner
per meter
832.9129
10
Fitting Quick Coupler
1 piece
832.9137
11
Fitting Quick Coupler
1 piece
832.9133
14
Reservoir Cap (included with Item 1)
-
832.9120
N/S
Injector Body Rebuild Kit
-
832.9118
N/S
Extension Hose Kit 35'
-
832.9100-EXT
N/S
Anti-Spatter Fluid - Organic Oil Based - MSDS
1 Gallon
192.9017
N/S
Anti-Spatter Fluid - Organic Oil Based - MSDS
5 Gallon
192.9012
N/S
Anti-Spatter Fluid - Organic Oil Based - MSDS
55 Gallon
192.9007
-
-
-
-
-
N/S = Not Shown
-
-

TMS-PI ANTI-SPATTER SET-UP

1. Attach aluminum mounting bracket to a suitable location
2. Attach Anti-Spatter unit with 2 mounting screws supplied
3. Connect non-lubricated main air to air supply inlet 1/4" barb. Air pressure to be min. 60 PSI and max. 120 PSI
4. connect solenoid valve wires to 24VDC or 110VAC robot output or PLC output
5. Fill reservoir with suitable Anti-Spatter fluid. If unit has run dry - or to prime - open drain plug to allow liquid to run freely and bleed air from the unit. Unit is primed from the factory and normally will prime after filling the reservoir.
6. Connect outer hose to welding torch connection. Inner hose may lie freely and extend into the torch side hose.
FLUID / PULSE ADJUSTMENTS
1. Injector Stroke
- Rotate brass fluid adjustments knob to increase/decrease fluid quantity. Clockwise to increase - counterclockwise to decrease
2. Pulse Frequency
- adjust pulse frequency using standard screwdriver. Frequency range is from 4-200 pulses per minute

 

 

 

 